SEARCH     
 

Specifications of the CEO Four Plunger-Lift Controller

Analog Input Channels
Number of channels 6 inputs (1 to 5V or 4 to 20 mA conversion)
Accuracy 0.1% of full scale after factory calibration
  Switched analog voltage to transmitter(s)
Input impedance 2 Meg ohm, 12-bit resolution

Digital Input Channels
Number of channels 5 digital inputs
  3.3V open circuit
  165 mA short-circuit current
  Dry contact only, 1 K maximum

Digital Output Channels
Number of channels 8 digital outputs (4 pulsed latch valves)
Rated output 15V maximum, open collector output
  500 mA continuous current
  2-amp pulsed current
  Switched battery voltage to end device
(solenoid typical)

Communication Ports
RS-232 Human-machine interface
RS-232 Modbus communication
RS-485 Modbus communication

Power Consumption
Nominal 360 mW (30 mA at 12V)
Maximum 550 mW

Onboard Memory
Flash 8 MB, 512 K × 16
Static Ram (SRAM) 8 MB, 1 M × 8

Certifications

  • The CEO Four is CSA certified for Class 2258-02, Process Control Equipment for Hazardous Locations, Class I, Division 2, Groups A, B, C, and D.
  • The remote latch valve is CSA certified for Class I, Division 2.