Electrical Input Supply
Three-phase voltage 230, 380, 480 Vac (+10% to 15%)
Three-phase frequency 50 to 60 Hz (±5%)
Single-phase voltage 230, 480 Vac (±10% to 15%)
Single-phase frequency 50 to 60 Hz (±5%)

Electrical Power Factor
Displacement 1.00
Overall 0.94

Electrical Output Rating
Voltage Zero to input voltage, three-phase
Frequency Zero to 120 Hz open loop vector control
Zero to 300 Hz variable frequency control
Switching frequency Programmable, 2 to 16 kHz
Overload current 110 to 120% of rated for one minute (normal duty)

Electrical Conversion
Rectifier unit Six-diode, three-phase (six-pulse) full wave bridge below 40 Hp
Diode-SCR, 6-phase (12-pulse) full-wave bridge for 40 Hp and above
Inverter unit Six-IGBT, four-quadrant, trap or sine wave output

Environmental
Operating temperature -40° to 122°F (-40° to 40°C)
Storage temperature -4° to 140°F (-20° to 60°C)
Relative humidity 5% to 95%, non condensing
Altitude 0 to 3,300 ft. (1,000 m) at full rating

Inputs and Outputs
Analog inputs Three 12-bit analog inputs: one 4 to 20 mA, two 0 to 10 Vdc
Pulse input 0 to 32 kHz (flow volume configurable)
Analog outputs Two 12-bit analog outputs, 4 to 20 mA
Pulse output 0 to 32 kHz
Digital inputs Eight digital inputs (requires sink of 1 mA to common)
Digital outputs Three programmable relay outputs (1 A @ 250 Vac), one fault contact

Serial Communications
Modbus® RTU RS422/485, 1200 to 19200 baud (STD)

Dimensional Data
Sz HP Height
Width
Depth
Weight
    in. cm. in. cm. in. cm. lbs. kg.
1 5-30 36 91.44 24 60.96 18 45.72 200 90.72
2 40-50 48 121.92 24 60.96 18 45.72 240 108.86
3 60-100 48 121.92 30 76.2 18 45.72 280 127.0
4 125-150 60 152.4 36 91.44 20 50.8 350 158.76
5 200 72 182.88 42 106.68 20 50.8 440 199.58
© 2010 Weatherford International Ltd.