RMS-WH Wellhead Optical-Sensor Reservoir Monitoring System Specifications
| General |
| Number of P/T gauges monitoring capability* |
6 |
| Update rate selectable range |
1 sec to 15 min |
| Storage capacity |
> 2 yr |
| Units of measure (selectable) |
Metric, Imperial, oilfield |
| Output Options |
| MODBUS, serial 232, 422, 485, and TCP/IP |
ASCII, RTU, master or slave |
| Simple serial 232, 422, 485 |
ASCII |
| OPC 2.0 data access standard |
Client and server |
| Data files by LAN or WAN |
Flat-file or Web browser |
| Web-enabled data visualization and transfer |
LAN and Web browser |
| Direct SQL database access |
ODBC driver |
| Electrical Power |
| 24 V DC nominal |
18 to 32 V DC |
| Maximum current |
1.6 amp @ 24 V DC |
| Power consumption |
38 W |
| Physical |
| Zone 2 dimensions (in./mm) |
24W × 30H × 8D.
762W × 610H × 203D |
| Zone 2 weight (lb/kg) |
45
23 |
| Zone 1 dimensions (in./mm) |
29W × 35H × 13D
743W × 895H × 330D |
| Zone 1 weight (lb/kg) |
505
229 |
| Environmental |
| Operating temperature range (shaded) (°F/°C) |
–4° to +140°
–20° to +60° |
| Shipping and storage temperature range (°F/°C) |
–40° to 185°
–40° to +85° |
| Relative humidity, non-condensing |
95% |
| Transportation vibration |
3.0 g rms, random and sine |
*20,000-PSI (1,379-bar) P/T gauge
Overview
Specifications
Diagram
|
 |